Worcester Bosch Boiler Fault Codes
If your Worcester Bosch boiler is showing a fault code, this guide explains what it means, what you can safely check yourself and when to call a Gas Safe engineer. It is written by the team at Xbg Plumbing & Heating, Worcester Bosch accredited installers based in Rustington, West Sussex.
Worcester Bosch has built boilers in Worcester for more than 60 years and has been part of the Bosch Group since 1996. Its Greenstar range is one of the most common in UK homes, so we see these codes every week.
How Worcester Bosch Fault Codes Work
Most Greenstar boilers show a two-character fault code, such as EA or E9, with a three-digit cause code, such as 227 or 224. Press the spanner or return button to see the cause code. A flashing blue light on the display usually means the boiler has found a fault.
Locking faults show a warning triangle and need a reset once the cause is fixed. Blocking faults pause the boiler and clear on their own when the problem goes away.
Stay Safe
Never remove the boiler casing. Only a Gas Safe registered engineer should work on the gas parts inside. If you smell gas, leave the property and call the National Gas Emergency Service on 0800 111 999. You can check any engineer on the Gas Safe Register.
Common Worcester Bosch Fault Codes
The Worcester Bosch fault codes below cover Greenstar Si, i, Compact and CDi models. Fault code wording varies slightly between Worcester Bosch models, so check your boiler’s manual as well. Where a code mentions water pressure, the gauge should usually read around 1 to 1.5 bar when the heating is cold.
EA 227: No Flame After Ignition
The boiler tried to light four times and failed. Check your gas meter is on and other gas appliances work, and that the condensate pipe is not frozen. Then press reset once.
EA 229: Flame Lost During Operation
The flame went out while running. Common causes are a blocked condensate trap or strong wind blowing into the flue.
EA 261: Ignition Timing Error
No flame was detected in the first ignition period. If it keeps happening, the ignition parts need checking by an engineer.
EA 338: Too Many Short Burner Starts
The pump is not detecting enough water. Check the pressure gauge and top up to about 1 bar.
E9 224: Flue Gas Overheat
The flue gas thermostat or safety limiter has tripped. Low water pressure is a common cause, so top up and reset. Call an engineer if it returns.
E9 219: Safety Sensor Too Hot
The heat exchanger has overheated. Check the pressure and that radiator valves are open. Repeated faults need an engineer.
E5 218: Flow Temperature Too High
Water leaving the boiler is too hot, usually because it is not circulating properly. An engineer should check the pump and system.
E2 222: Flow Sensor Short Circuit
The flow temperature sensor has failed or its wiring is damaged. This needs an engineer.
D1 240: Return Sensor Error
The return sensor may be wet or damaged. The boiler waits five minutes before locking out. Call an engineer.
C6 215 / 216: Fan Speed Fault
The fan is running too fast (215) or too slow (216). This is an internal fault for a Gas Safe engineer.
C6 214 / 217: Fan Not Running
The fan has not started, or airflow is blocked. Check the flue outside is clear, then call an engineer.
C1 264: Airflow Stopped
The fan stopped while the boiler was running. If it happens more than once, book an engineer.
A1 281: Pump Stuck or Running Dry
There is little or no water in the system. Repressurise to about 1 bar and look for any leaks.
No Code 212: Temperature Rising Too Fast
Usually an air lock or low water content. Top up the pressure and bleed any radiators that feel cold at the top.
No Code 260: No Temperature Rise
The burner lit but the water did not heat up. Check the pressure; if it is fine, a sensor may need replacing.
F7 228: False Flame Signal
The boiler detected a flame before the burner started. Often moisture on the electrode or a failing part. Engineer required.
FA 306: Flame After Shut-Off
A flame signal continued after the gas valve closed. The gas valve needs checking by a Gas Safe engineer.
FD 231: Power Interruption
The power was interrupted or the reset button was pressed by mistake. Press reset again.
B7 257: Internal Control Error
The control board has reported an internal error. This needs an engineer and may mean a replacement board.
9U 233: Code Plug Fault
The code plug that tells the boiler its model and settings is faulty or loose. Engineer required.
EF 349: Large Temperature Difference
Flow and return temperatures differ by more than 18°C at low output. Often air or poor circulation in the system.
1017 W: Water Pressure Too Low
Shown on Greenstar 8000 models. Top up the system pressure and check for leaks if it keeps dropping.
H11: Hot Water Sensor Fault
A maintenance code. Hot water still works, but with less precise temperature control. Mention it at your next service.
H13: Service Reminder
The boiler is due its annual service. It keeps working, but book a service to keep your warranty valid.
Seeing the Same Worcester Bosch Fault Code Again?
If your boiler keeps showing the same Worcester Bosch fault code, or it is more than 10 years old, a repair may only buy you a few months. Our Worcester Bosch accredited engineers can fix the fault or quote for a replacement, with guarantees of up to 12 years on selected models. Read about our boiler repairs or new boiler installations.
Fault code you can’t clear? Call 01903 536502 and speak to a Gas Safe engineer.
Does my boiler need to be replaced?
We believe in an transparent and honest approach with all our customers, so will always give you the best advice if your boiler needs replacing. There can be a variety of different reasons that will help identify that your boiler may need replacing. The pilot on your pilot light should burn blue, in the event that’s it’s a different colour, then please call us right away.
Additionally, if you notice strange noises from either the boiler or radiators. You may suddenly hear an increase in noise level, this indicates a problem and needs attention by a qualified gas engineer. Finally, and just as important as the other points, any evidence of any leaks or strange smells coming from your boiler, should be treated as urgent. Please call us 01903 536 502, so we can advise you on the next steps.
Worcester Bosch Fault Code FAQs
These are the questions we are asked most often about Worcester Bosch fault codes. If your question is not here, our Gas Safe engineers are happy to help on 01903 536502.
How do I reset my Worcester Bosch boiler?
Press the reset button on the control panel, which is usually marked reset or shown with a flame symbol. If the same code comes straight back, stop resetting and call a Gas Safe engineer.
Why is my Worcester Bosch boiler flashing blue?
A flashing blue light usually means the boiler has detected a fault. Check the display for a fault code and look it up in the list above.
What pressure should my Worcester Bosch boiler be?
Around 1 to 1.5 bar when the heating is cold is typical for most Greenstar models. If it keeps dropping below 1 bar, there may be a leak in the system.
What does EA 227 mean on a Worcester Bosch boiler?
EA 227 means no flame was detected after ignition. Common causes are a gas supply problem, a frozen condensate pipe or an ignition fault.
Can I fix a Worcester Bosch fault code myself?
You can check and top up the pressure, thaw a frozen condensate pipe with warm (not boiling) water and press reset. Anything inside the casing needs a Gas Safe registered engineer.
Still stuck with a fault code? Call 01903 536502 to book a Worcester Bosch accredited engineer.
Boiler Types Explained
Combi boiler
A combination or ‘combi’ boiler is both a high efficiency water heater and a central heating boiler in a single compact unit. Combi boilers heat water directly from the mains when you turn on a tap, so you won’t need a hot water storage cylinder or a cold water storage tank in the roof space.
They are also very cost-effective and energy-efficient as water is heated instantly rather than being heated and then stored in a cylinder. An added benefit is that hot water is delivered at mains pressure, which means that you could get a powerful shower without the need for a separate pump.
System boiler
System boilers require a cylinder for storing hot water, however the major heating and hot water system components are built into the boiler itself, making it quicker and easier to install. In addition, there is no need for a tank in the loft, so it can be an option in a home with little or no loft space or where the space is earmarked for a conversion.
These boilers are also compatible with solar water heating systems, which deliver environmental benefits as well as lower energy bills.
Regular boiler
Regular boilers (sometimes known as traditional, conventional or heat only boilers) are ideally suited to homes that already have a traditional heating and hot water system which is linked to a separate hot water cylinder. These boilers also need a cold water storage tank in the loft to feed the hot water cylinder as well as a tank that maintains the water level of the central heating system.
A regular boiler may be the best option for replacing an existing boiler if the property has an older radiator system, as it might not be able to cope with the higher water pressure that is delivered by system or combi boilers